P A T E N T E D T E C H N O L O G Y
866.591.1059
Home
Company Profile
Profile/History
Project Portfolio
Manufacturing
Testing
Overview Presentation
Contact Us
Products
HydroFlame Sleeves
Corrugated Sleeves
HydroPreseal Seals
HydroFlame Tub Box
Product Price Sheet
Warranty/Terms of Sale
Tech Data
Product Data Sheets
Architectural & Piping Specs
UL Systems
CAD Drawings
Technical Articles
HydroFlame Installation
Tools
Online Quotes
Quote Review/Reprint
Cost Compare Calculator
Submittal Generator
Sleeve Dimensions
Binder Registration
Tech CD Software
Benefits
Why HydroFlame
Builder, Developer
Contractors
Owner
Architect
CAD DRAWINGS
 


(1) Exterior, Non-Rated wall, Water Tight Sleeve, w/ base, B&W

Air tight, exterior pass-through Sleeve, Hydro-Preseal, with base for mounting to concrete forms.

DWG

 
 


(2) Slab on grade, Non-Rated Water Tight Sleeve, w/ base, B&W

Water/Air tight, exterior pass-through sleeve, Hydro-Preseal, with base stand, for Slab on Grade.

DWG

 
 

(3) Slab on grade, Non-Rated Water Tight Sleeve, wo/ base, B&W

Water/Air tight, pass-through sleeve for Slab on Grade, Hydro-Preseal.

DWG

 
 


(4) Exterior, Non-Rated wall, Water Tight Sleeve, wo/base, B&W

Water/Air tight sleeve, for exterior pass-through, Hydro-Preseal, for tying to rebar in concrete forms.

DWG

 
 
 

(5) Floor 3Hour F-Rated, Water Tight Sleeve, B&W

Water/air/smoke tight pass-through device, Hydroflame, three hour rated, for metallic or plastic pipes. No additional caulk or mineral wool required.

UL systems F-A-1097 & F-A-2176

DWG

 
 

(6) Floor, Water Tight Sleeve, Metallic Pipe w/ Insulation, B&W

Water/air/smoke tight pass-through device, Hydroflame, for metallic pipes only, with insulation. No additional caulk or mineral wool required. Sealant is required only for maintaining a vapor barrier and is not necessary for piping where a vapor barrier is not required. Sealant is used in lieu of passing the insulation completely through the sleeve. The sealant is an insulation-compatible vapor barrier sealant, as recommended by the manufacturer of the insulation.

DWG

 
 

(7) Corrugated Floor, Water/Smoke/Air Tight Sleeve, B&W

Water/air/smoke tight pass-through device, Hydroflame, for metallic pipes only, passing through concrete floor, over metal deck, with insulation. No additional caulk or mineral wool required. Sealant is required only for maintaining a vapor barrier and is not necessary for piping where a vapor barrier is not required. Sealant is used in lieu of passing the insulation completely through the sleeve. The sealant is an insulation-compatible vapor barrier sealant, as recommended by the manufacturer of the insulation.

UL systems F-A-2182 & F-A-1104

DWG

 
 

(8) Corrugated Floor, Water/Smoke/Air Tight Sleeve, for metallic, insulated pipe, B&W

Water/air/smoke tight pass-through device, Hydroflame, for metallic pipes only, passing through concrete floor, over metal deck, with insulation. No additional caulk or mineral wool required. Sealant is required only for maintaining a vapor barrier and is not necessary for piping where a vapor barrier is not required. Sealant is used in lieu of passing the insulation completely through the sleeve. The sealant is an insulation-compatible vapor barrier sealant, as recommended by the manufacturer of the insulation.

UL systems F-A-2182 & F-A-1104

DWG

 
 

(9) Tub Box, Water Tight, 1.5” Drain, w/Tub, B&W

Water/air/smoke tight, dual water barrier, combination Bathtub drain box out device and pass through device for a 1.5” tub drain, Hydroflame Tub Box, Detail shows tub box and bathtub. Hooks up to a standard 2” drain system, adapts easily to metallic pipe.

UL systems F-A-1103 & F-A-2183

DWG

 
 

(10) Tub Box, Water Tight, w/ 1-1/4” drain, w/Tub, B&W

Water/air/smoke tight, dual water barrier, combination Bathtub drain box out device and pass through device for a 1-1/4” tub drain, Hydroflame Tub Box, Detail shows tub box and bathtub. Hooks up to a standard 2” drain system, adapts easily to metallic pipe.

UL systems F-A-1103 & F-A-2183

DWG

 
 

(11) Tub Box, Water Tight, w/ 1.5” drain, wo/Tub, B&W

Water/air/smoke tight, dual water barrier, combination Bathtub drain box out device and pass through device for a small tub drain, Hydroflame Tub Box, Detail shows tub box without the bathtub. Hooks up to a standard 2” drain system, adapts easily to metallic pipe.

UL systems F-A-1103 & F-A-2183

DWG

 
 

(12) Tub Box, Water Tight, w/ 1-1/4” drain, wo/Tub, B&W

Water/air/smoke tight, dual water barrier, combination Bathtub drain box out device and pass through device for a small 1-1/4” tub drain, Hydroflame Tub Box, Detail shows tub box without the bathtub. Hooks up to a standard 2” drain system, adapts easily to metallic pipe.

UL systems F-A-1103 & F-A-2183

DWG

 
 

(13) Closet Flange , Water Tight Sleeve, w/ 3" & 4" Closet Flange, B&W

Water/air/smoke tight pass-through device, Hydroflame, three hour rated, for metallic or plastic pipes. No additional caulk or mineral wool required.

UL system F-A-2189

DWG

 
 

(14) Shower Drain Sleeve, w/ 2" drain, B&W

Shower Drain pass-through device, 3 hour fire rated, for plastic pipes. No additional caulk or mineral wool required.

UL system F-A-2190

DWG

 
 

(15) Line Set Sleeve, B&W

Pass-through device, 3 hour fire rated, for use with metallic or plastic line sets.

UL system F-A-8034

DWG

 
 

(16) Cable Chase Sleeve, B&W

Pass-through device, 3 hour fire rated, for use with all electrical and signal cables.

UL system F-A-3052

DWG

 